FR Synergist

general-use Sb2O3 antimony trioxide total replacement alternative substitute

author:Novista  time:2026-7-17 9:35:01 visits:1 
general-use Sb2O3 antimony trioxide total replacement alternative substitute

PRODUCT DETAILS

ProFlame® RTF-100

 

Sb2O3 is commonly used as synergist in halogenated FR systems. But as antimony reserves worldwide are decreasing, Sb2O3 price is rising all the way up. RTF-100 is a replacement of Sb2O3. It can completelyreplace Sb2O3 in halogen-antimony FR systems in an effective way with lower cost.fective way with lower cost.

 

Physical and Chemical Index:

Product name

RTF-100

Whiteness,%

>95

Average Particle size,um

<2.0

Moisture,%

<0.1

As2O3,%

<0.04

PbO,%

<0.065

Fe2O3,%

<0.004

Se,%

<0.0015

CuO,%

<0.0035

 

Characters:

1.  High  purity,  high  specific  surface  area,  ultrafine  particles’  surface  effect  and  volume  effect,  good

thermal stability, no skin irritation, no odor, no corrosion.

2.  Good heat resistance

3.  RTF-100 can  help  to  maintain  products’  mechanical  and  electrical  performance  in  hot  and damp

environment.

 

Application Range:

It is mainly used in PP,PE,ABS,HIPS,PA,PBT,PVC and so on

 

Package

25kg plastic woven bag or paper bag with PE liner bag.

 

Storage considerations:

The product can be stored under appropriate conditions for two years. But please keep products store in a dry ventilated environment (temperature should not exceed 30°C, in low humidity).


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

RTF-100 used in PBT

We can find Sb2O3 can be replaced by RTF-100 completely, the FR performance is well maintained.

The most significant change is the enhanced MFI with the dosage of RTF-100, which is good for the later molding process, while other mechanical properties are basically unchanged.

 

 

Table 1: RTF-100 used in PBT (formula)



1

2

PBT%

58

57.5

DBDPE%

9

9

Sb2O3%

3

0

RTF-100

0

3.0-3.3

Other additive

5

5

 

 

 

Table 2: RTF-100 used in PBT (test result)


Test standard

1

2

Tensile strength

GB/T1040-1992

104

107

Elongation at break

GB/T1040-1992

2.1

2.2

Bending strength

GB/T9341-2000

137

137

Bending modulus

GB/T9341-2000

7981

8100

Notched impact strength

GB/T1843-1996

8.2

8.3

HDT

GB/T1634-2004

219

221

Melt index

GB/T3682-2000

27.3

29.8

FR grade

UL-94

V-0

V-0

Ash content

GB/T9345-1988

24.3

24.9

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

RTF-100 used in PA66

We can find Sb2O3 can be replaced by RTF-100 completely, the FR performance is well maintained.

The most significant change is the enhanced MFI with the dosage of RTF-100,which is good for the later molding process,while other mechanical properties are basically unchanged.

 

 

 Table 3: RTF-100 used in PA66 (formula)


3

4

PA66%

56.5

56

DBDPE%

10

10

Sb2O3%

3.5

0

RTF-100%

0

3.5-4.2

Other additive

5

5

GF%

25

25

 

 

 

Table 4: RTF-100 used in PA66 (test result)


Test standard

3

4

unit

Tensile strength

GB/T1040-1992

144

148

MPa

Elongation at break

GB/T1040-1992

2.8

2.7

%

Bending strength

GB/T9341-2000

183

192

MPa

Bending modulus

GB/T9341-2000

7670

7709

MPa

Notched impact strength

GB/T1843-1996

15.3

15.7

KJ/m2

HDT

GB/T1634-2004

253

254

FR grade

UL-94

V-0

V-0

/

Ash content

GB/T9345-1988

25.6

24.7

%


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

RTF-100 used in ABS

We can find Sb2O3 can be replaced by RTF-100 completely, the FR performance is well maintained.

The most significant change is the enhanced MFI, enhanced notch impact strength, and lower material density with the dosage of RTF-100, which is good for the later molding process, while other mechanical properties are basically unchanged.

 

 

 Table 5: RTF-100 used in ABS (formulas)


5

6

ABS%

81

80

DBDPE%

12

12

Sb2O3%

4

0

RTF-100%

0

4.0-5.0

Other additive

3

3

 

 

 

Table 6: RTF-100 used in ABS (test results)


Test standard

5

6

Tensile strength

GB/T1040-1992

39.3

40.5

Elongation at break

GB/T1040-1992

18.6

19.8

Bending strength

GB/T9341-2000

58

58

Bending modulus

GB/T9341-2000

2491

2493

Notched impact strength

GB/T1843-1996

12.1

12.3

Melt index

GB/T3682-2000

3.1

4.2

FR grade

UL-94

V-0

V-0

Density

GB/T1033-1986

1.20

1.17

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

RTF-100 used in HIPS

We can find Sb2O3 can be replaced by RTF-100 completely, the FR performance is well maintained.

The most significant change is the enhanced MFI, enhanced notch impact strength, and lower material density with the dosage of RTF-100, which is good for the later molding process, while other mechanical properties are basically unchanged.

 

 

 Table 7: RTF-100 used in HIPS (formulas)


7

8

HIPS%

79

78.5

DBDPE%

13

13

Sb2O3%

4.5

0

RTF-100%

0

4.5-5.0

 

 

 

Table 8: RTF-100 used in HIPS (test results)


Test standard

7

8

Tensile strength

GB/T1040-1992

24.3

24.8

Elongation at break

GB/T1040-1992

49

56

Bending strength

GB/T9341-2000

43

43

Bending modulus

GB/T9341-2000

2180

2205

Notched impact strength

GB/T1843-1996

11.8

12.1

Melt index

GB/T3682-2000

8.8

9.1

FR grade

UL-94

V-0

V-0

Density

GB/T1033-1986

1.15

1.14

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

RTF-100 used in PP

According to the dosage table 7 and sample test result table 8, we can find enhanced MFR(melt  flow  rate),  enhanced  notch  impact  strength,  and  significantly  lower material density with the increased dosage of RTF-100.

And,  when  1/3  or  less  the  dosage  of  Sb2O3  is  replaced  by  RTF-100,  the FR performance is well maintained.

Moreover, PP added with RTF-100 is whiter than with Sb2O3 alone, with enhanced surface glossiness and coloring performance.

Besides, as RTF-100 is an ultra-fine inorganic powder, it can perform nucleation effect in PP compounding, reducing the molding cycle, improving material distortion temperature. At the same time it can reduce the dosage of special nucleating agent in the compounding process, thus furtherly reducing the production cost.

 

 

 Table 9: RTF-100 used in PP (formula)


9

10

PP%

60

58.5

DBDPE%

18

18

Sb2O3%

6

0

RTF-100%

0

6.0-7.0

Other additives

16

16

 

 

 

Table 10: RTF-100 used in PP (test result)


Test standard

9

10

Tensile strength

GB/T1040-1992

24.3

23.9

Elongation at break

GB/T1040-1992

32

34

Bending strength

GB/T9341-2000

36

37

Bending modulus

GB/T9341-2000

2209

2158

Notched impact strength

GB/T1843-1996

3.6

3.7

Melt flow index

GB/T3682-2000

9.4

10.2

HDT

GB/T1634-2004

130

130

FR grade

UL-94

V-0

V-0

Density

GB/T1033-1986

1.23

1.22

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

RTF-100 used in PVC

According to table 9, Oxygen index retention of 97% when RTF-100 replaces Sb2O3 completely with 1:1 ratio in the formulation.

 

 

 

Table 11: RTF-100 used in PVC wire and cable (formula)

Material

1-1

1-2

2-1

2-2

3-1

3-2

PVC (K=71-72)

100

100

100

100

100

100

DOP

35

35

35

35

35

35

CP-52

15

15

15

15



CP-70





15

15

CaCO3

30

30



30

30

ATH



30

30



Ca/Zn Stabilizer

5

5

5

5

5

5

Sb2O3

5

0

5

0

5

0

RTF-100


5


5


5

LOI,%

32.4

31.6

34.3

33.2

34.5

33.1

 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

 

 

Conclusion

RTF-100  can  completely  replace  Sb2O3  with  1-1.15/1.0   ratio  in  the  bromine antimony based flame retardant modification of many plastic types


news